MOST User-Friendly Design


1. Flip 2 switches
2. Lay out the hose
3. Place vapor barrier & insulation


That’s it! No complicated manifolds. No valves to
open or close. No hoses to connect. Why do it the
hard way? Ground Heaters’ long hoses allow easy,
flexible setup for all applications.


It doesn’t get any easier than a
Ground Heater.

 

Ground Heaters Deliver the Most Heat
1 pump per hose loop (fastest flow rate)

+ Highest net BTU’s (super-efficient heater)

= Most BTU’s to job surface
(for fast thawing and consistent concrete curing)
 

Based on years of testing and experience, Ground Heaters products are the most efficient, durable, and user-friendly portable hydronic heating systems available.
machine details machine specifications

pdf product sheet

job studies

•  Thaw ground - quickly, easily, and economically

- 1,100 - 2,200 sq. ft. with standard equipment
- up to 3,300 sq. ft. in ½ the time with accessories*

*Varies based on soil conditions.  Complete a Ground Heaters’ Thaw Cost Plan.

•  Cure concrete - in cold weather with confidence

- up to 2,200 sq. ft. with standard equipment
- up to 6,000 sq. ft. with accessories*

*Varies based on application.  Complete a Ground Heaters’ Cure Cost Plan.

•  Prevent Frost – large areas, very economically

- up to 3,300 sq. ft. standard
- up to 9,900 sq. ft. with accessories

•  Heat workspace – dry heat and fuel efficient

- up to 180,000 cu. ft. with accessories*

*Varies based on application.  Ask your dealer for an Air Heat Cost Estimate.

•  Up to 115 hours run-time

•  Engineered for reliable, trouble-free start

•  Easy to operate

•  Economical

•  Dependable

•  Built Tundra Tough™

•  87% heater efficiency - highest in the industry

 

Ground Heaters have changed cold weather construction forever!
 
Thaw and cure large areas:
• Thaw up to 1 Ft. deep/day (dependent on conditions)
• Set, finish and cure concrete like it’s summer

• Protect newly poured concrete from frost

 

Add Optional Accessories to Thaw Faster, Cure Larger Areas, or Heat Workspace

Hose Handling Systems

Easy use and storage of additional Heat Transfer Hose

 

Pump Packs

Thaw faster; provide uniform heat for curing  large areas of concrete; single or dual

 

Heat  Xchangers

Provide temporary air heat for interior workspaces; 3 sizes

 

To heat larger spaces, ask about NEW Arctic Bear and Pureheat Air Heaters.

 

Machine Details

Positive Displacement Pumps

Positive Displacement Pump:

provides maximum flow and assures consistent heat delivery for thawing and curing. One pump per hose loop means more BTU’s/Hr delivered to project than other hydronic heaters. Plenty of power to pump Heat Transfer Fluid 250 feet up from Ground Heater, allowing Ground Heater to remain below cure site (such as a bridge deck).

Performance Monitoring System

Performance Monitoring System:

strobe light indicates from a distance that all systems are operating properly. Can be connected to dialer, transmitter, or other remote alert device.

Digital Temperature Controller

Digital Temperature Controller:

with push button adjustment. Allows operator to easily adjust Heat Transfer Fluid output temperature for all applications.

NEW Gauge "Dashboard"

NEW Gauge Positions:

All gauges are easily viewed in this new “dashboard” design.

NEW E1100 "Generator"

NEW Generator:

Optional 3kw liquid-cooled diesel
generator is available.New smart
load feature maximizes engine
performance.

Specifications
Dimensions and capacities
Length - hitch assembly extended
Length - hitch assembly folded
Width
Height
Ground clearance
Approx. weight w/o fuel
Approx. weight with fuel
Fuel capacity
Heat Transfer Fluid
Pump, 265 US GPH positive displacement
Hose
Hose reel
Hose rewind
Circulation loop
Tires
Hitch
Lifting bar
Fork lift pockets
114”
88”
65”
61”
10”
1,992 lbs/2,252 lbs
2,456 lbs/2,716 lbs
72 US GAL
50 US GAL
1
1,100 ft
1
120V AC, w/ 12V DC clutch
1
ST185/80D13
2” ball
yes
both rear and sides
Additional Information
Tie downs
Ground fault interrupt
Main circuit breaker
Burner motor thermal protection
Burner ignition
High temperature shutdown
No-flame shutdown
Low fluid shutdown/warning light
Vented closed loop circulation
Hydronic heater operating pressure
Temperature gauges
Pressure gauges

 

 

5
yes
1
auto reset
electronic
yes
yes
yes
yes
0 psi
1
1
Performance
Heater, gross output
Heater, net output
Heater efficiency
Temperature controller
Fuel consumption at full load
Fuel requirement
Run time
Electrical requirement*
Normal operating temp
Normal hose operating pressure
 
126,000 BTU/H
110,000 BTU/H
87%
digital
90/1.32 US GPH
winter blend diesel
up to 115 hours
1 x 20 amps x 120V AC
100ºF - 180ºF
70 - 90 psi
 


All specifications are subject to change without prior notice.

 

 
HTF flow rate per loop
Thawing capacity (standard)
Thawing capacity (with accessories)
Curing capacity (standard)
Curing capacity (with accessories)
Frost Prevention (std equipment)
Frost Prevention (w/ accessories)
Air heat capacity (with accessories)
Performance monitoring system
265 US GPH
1,100 – 2,200 sq ft
2,200 - 3,300 sq ft
2,200 sq ft
up to 6,000 sq ft
up to 3,300 sq ft
up to 9,900 sq ft
180,000 cu ft
yes

 

Your Ground Heater dealer carries a complete line of parts
and accessories and will help you configure a
Ground Heater
system to best suit your needs. 

The E1100 Ground Heater is   certified, and complies with
US NHTSA
and Transport Canada regulations.

copyright © 1998-2008 Ground Heaters

 