|

|

|
MOST User-Friendly Design |
|
1. Flip 2 switches
2. Lay out the hose
3. Place vapor barrier & insulation
That’s it! No complicated manifolds.
No valves to
open or close. No hoses to connect. Why do it the
hard way? Ground Heaters’ long hoses allow easy,
flexible setup for all applications.
It doesn’t get any easier than a
Ground Heater.
™
|
|
Ground
Heaters
Deliver the Most Heat |
|
|
1 pump per hose loop
(fastest flow rate)
+ Highest net
BTU’s (super-efficient
heater)
= Most BTU’s to job surface
(for fast thawing and consistent
concrete curing)
|
|
Based
on years of testing and experience, Ground Heaters
products are the most efficient, durable, and
user-friendly portable hydronic heating systems
available. |
|
|
|
|
| •
Thaw ground
- quickly,
easily, and economically |
- 1,100 - 2,200 sq.
ft. with standard equipment
- up to 3,300 sq. ft. in ½ the time with accessories*
*Varies based on soil conditions. Complete a Ground
Heaters’ Thaw Cost Plan.
|
|
• Cure concrete -
in cold weather with confidence |
- up to 2,200 sq. ft.
with standard equipment
- up to 6,000 sq. ft. with accessories*
*Varies based
on application. Complete a Ground Heaters’ Cure
Cost Plan.
|
| •
Prevent Frost
– large
areas, very economically |
- up to 3,300
sq. ft. standard
- up to 9,900 sq.
ft. with accessories
|
| •
Heat workspace
– dry heat
and fuel efficient |
- up to 180,000 cu.
ft. with accessories*
*Varies
based on application. Ask your dealer for an Air Heat Cost Estimate.
|
|
|
• Up to 115 hours run-time
• Engineered for reliable,
trouble-free start
• Easy to operate
• Economical
• Dependable
• Built Tundra Tough™
• 87% heater efficiency -
highest in the industry |
Ground Heaters
have changed cold weather construction forever!
| |
| Thaw and cure
large areas: |
• Thaw up to 1 Ft.
deep/day (dependent
on conditions)
• Set, finish and cure concrete like it’s summer
• Protect newly poured concrete from frost |
|
|
|
|
|
Add Optional Accessories to Thaw Faster,
Cure Larger Areas, or Heat
Workspace |
 |
  |
 |
|
Hose Handling Systems
Easy use and storage of
additional Heat Transfer Hose
|
Pump Packs
Thaw faster; provide
uniform heat for curing large areas of concrete; single or dual |
Heat Xchangers™
Provide temporary air heat for interior workspaces; 3 sizes
|
|
To heat
larger spaces, ask about
NEW
Arctic Bear and
Pureheat
Air Heaters™.
|
|
Machine Details
|

Positive Displacement Pumps |
Positive Displacement Pump:
provides maximum flow and assures
consistent heat delivery for thawing and curing. One pump per
hose loop means more BTU’s/Hr delivered to project than other
hydronic heaters. Plenty of power to pump Heat Transfer Fluid
250 feet up from Ground Heater, allowing Ground Heater to remain
below cure site (such as a bridge deck). |

Performance Monitoring System |
Performance Monitoring System:
strobe light indicates from a
distance that all systems are operating properly. Can be
connected to dialer, transmitter, or other remote alert device. |

Digital Temperature Controller |
Digital Temperature Controller:
with push button adjustment. Allows
operator to easily adjust Heat Transfer Fluid output temperature for
all applications. |

NEW Gauge "Dashboard" |
NEW Gauge Positions:
All gauges are easily viewed in
this new “dashboard” design. |

NEW E1100 "Generator" |
NEW Generator:
Optional 3kw liquid-cooled diesel
generator is available.New smart
load feature maximizes engine
performance.
|
|
|
Specifications
|
|
Dimensions and capacities |
Length -
hitch assembly extended
Length - hitch assembly folded
Width
Height
Ground clearance
Approx. weight w/o fuel
Approx. weight with fuel
Fuel capacity
Heat Transfer Fluid
Pump, 265 US GPH positive displacement
Hose
Hose reel
Hose rewind
Circulation loop
Tires
Hitch
Lifting bar
Fork lift pockets |
114”
88”
65”
61”
10”
1,992 lbs/2,252 lbs
2,456 lbs/2,716 lbs
72 US GAL
50 US GAL
1
1,100 ft
1
120V AC, w/ 12V DC clutch
1
ST185/80D13
2” ball
yes
both rear and sides |
|
|
Additional Information |
Tie downs
Ground fault interrupt
Main circuit breaker
Burner motor thermal protection
Burner ignition
High temperature shutdown
No-flame shutdown
Low fluid shutdown/warning light
Vented closed loop circulation
Hydronic heater operating pressure
Temperature gauges
Pressure gauges
|
5
yes
1
auto reset
electronic
yes
yes
yes
yes
0 psi
1
1 |
|
|
Performance |
Heater,
gross output
Heater, net output
Heater efficiency
Temperature controller
Fuel consumption at full load
Fuel requirement
Run time
Electrical requirement*
Normal operating temp
Normal hose
operating pressure
|
126,000 BTU/H
110,000 BTU/H
87%
digital
90/1.32 US GPH
winter blend diesel
up to 115 hours
1 x 20 amps x 120V AC
100ºF - 180ºF
70 - 90 psi
|
All specifications are subject to change
without prior notice. |
|
| |
HTF flow rate per loop
Thawing capacity (standard)
Thawing capacity (with accessories)
Curing capacity (standard)
Curing capacity (with accessories)
Frost Prevention (std equipment)
Frost Prevention (w/ accessories)
Air heat capacity (with accessories)
Performance monitoring system |
265 US GPH
1,100 – 2,200 sq ft
2,200 - 3,300 sq ft
2,200 sq ft
up to 6,000 sq ft
up to 3,300 sq ft
up to 9,900 sq ft
180,000 cu ft
yes |
|
Your Ground Heater dealer
carries a complete line of parts
and accessories and will help you configure a
Ground
Heater
system
to best suit your needs.
The E1100
Ground
Heater is
certified,
and complies with
US NHTSA
and
Transport
Canada
regulations. |
|
|